{"id":33166,"date":"2023-08-08T11:37:12","date_gmt":"2023-08-08T03:37:12","guid":{"rendered":"https:\/\/en.hi-target.com.cn\/?p=33166"},"modified":"2025-10-16T09:01:56","modified_gmt":"2025-10-16T09:01:56","slug":"iflow-rp600-adcp-in-high-sand-flow-measurement","status":"publish","type":"post","link":"https:\/\/www.hi-target.com.cn\/es\/case-study\/hydrography\/iflow-rp600-adcp-in-high-sand-flow-measurement","title":{"rendered":"Aplicaci\u00f3n del ADCP iFlow RP600 en la medici\u00f3n del alto caudal de arena del r\u00edo Amarillo"},"content":{"rendered":"<p style=\"text-align: center;\"><span style=\"color: #ff0000; font-size: 14pt;\"><strong><a style=\"color: #ff0000;\" href=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2025\/10\/ADCP-in-high-sand-flow-measurement-of-Yellow-River.pdf\" download=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/ADCP-in-high-sand-flow-measurement-of-Yellow-River.pdf\">HAGA CLIC AQU\u00cd PARA DESCARGAR ESTE ESTUDIO DE CASO<\/a><\/strong><\/span><\/p>\n<p><em><span style=\"color: #999999;\">El ADCP (Perfilador Ac\u00fastico de Velocidad Doppler) es uno de los equipos de medici\u00f3n de caudal y velocidad fluvial m\u00e1s avanzados del mundo. Utiliza el principio del efecto Doppler para medir la velocidad del caudal y ayuda a los departamentos hidrol\u00f3gicos a obtener informaci\u00f3n sobre la velocidad y el caudal fluvial en l\u00ednea y en tiempo real. Mediante el ADCP, el departamento puede comprender el estado de funcionamiento y las leyes cambiantes de los r\u00edos, proporcionar datos fiables para la prevenci\u00f3n y el control de inundaciones, minimizar o evitar las v\u00edctimas y las p\u00e9rdidas materiales causadas por inundaciones y garantizar la seguridad de las personas y los bienes.<\/span><\/em><\/p>\n<h2><em><span style=\"color: #186bb5;\"><strong>Antecedentes del proyecto<\/strong><\/span><\/em><\/h2>\n<p>La Estaci\u00f3n Hidrol\u00f3gica de Luokou, ubicada en la ribera sur del dique del r\u00edo Amarillo, en la ciudad de Luokou, Jinan, provincia de Shandong, ha monitoreado e informado sobre los reg\u00edmenes h\u00eddricos para la Defensa General Nacional y la Defensa General del R\u00edo Amarillo durante todo el a\u00f1o, brindando informaci\u00f3n hidrol\u00f3gica precisa para el control de inundaciones y el alivio de sequ\u00edas, la programaci\u00f3n h\u00eddrica, la construcci\u00f3n de ingenier\u00eda y el desarrollo econ\u00f3mico local en el curso bajo del r\u00edo Amarillo en Shandong. Debido a la llegada de la temporada de inundaciones, afectada por la regulaci\u00f3n h\u00eddrica y sedimentaria y la erosi\u00f3n del curso alto del r\u00edo Amarillo, el agua en la secci\u00f3n oriental del r\u00edo Amarillo presenta una gran concentraci\u00f3n de sedimentos, y el caudal y la descarga aumentan, lo que hace que la Estaci\u00f3n Hidrol\u00f3gica de Luokou se enfrente constantemente al problema de la medici\u00f3n del caudal en un entorno con una gran concentraci\u00f3n de sedimentos.<\/p>\n<h2><em><span style=\"color: #186bb5;\"><strong>An\u00e1lisis de puntos de dolor<\/strong><\/span><\/em><\/h2>\n<p>En entornos con alta concentraci\u00f3n de sedimentos, el corrent\u00edmetro y el ADCP de la estaci\u00f3n hidrol\u00f3gica de Luokou no pueden probarse con normalidad. La prueba del corrent\u00edmetro requiere un tiempo prolongado, de aproximadamente una hora, y el m\u00e9todo de prueba es relativamente complejo, con altos requisitos para la secci\u00f3n de prueba. Adem\u00e1s, el corrent\u00edmetro requiere mucha mano de obra, lo que obliga a los operadores a conducir la embarcaci\u00f3n de prueba, adem\u00e1s de ciertos riesgos ocultos para la seguridad personal. Sin embargo, cuando el ADCP se enfrenta a una alta concentraci\u00f3n de sedimentos, la se\u00f1al ac\u00fastica transmitida se absorbe r\u00e1pidamente y no se pueden obtener ecos efectivos, lo que impide medir la informaci\u00f3n de seguimiento del fondo y dificulta la obtenci\u00f3n de datos de caudal y caudal.<\/p>\n<h2><em><span style=\"color: #186bb5;\"><strong>Programa de Implementaci\u00f3n<\/strong><\/span><\/em><\/h2>\n<p>Debido a las duras condiciones de la alta concentraci\u00f3n de sedimentos en el R\u00edo Amarillo, el ADCP no cuenta con informaci\u00f3n de seguimiento del fondo y no puede probarse por separado. Por lo tanto, Hi-Target proporcion\u00f3 la soluci\u00f3n iFlow RP600 ADCP, equipada con una ecosonda de doble frecuencia HD-MAX DF y un RTK dividido de alta precisi\u00f3n K20.<br \/>\nEn este esquema, la ecosonda de doble frecuencia HD-MAX DF mide la informaci\u00f3n de profundidad del agua y complementa los par\u00e1metros de profundidad en la informaci\u00f3n de seguimiento de fondo ADCP. El RTK dividido de alta precisi\u00f3n K20 mide la velocidad y complementa la velocidad relativa del equipo en la informaci\u00f3n de seguimiento de fondo ADCP. Los datos de medici\u00f3n de cada dispositivo se env\u00edan al software de medici\u00f3n de caudal iFlow en tiempo real mediante el software de compatibilidad de la ecosonda de doble frecuencia HD-MAX DF y el RTK dividido de alta precisi\u00f3n K20. Estos datos se integran con la informaci\u00f3n de velocidad relativa del caudal medida por el ADCP iFlow RP600 para calcular el caudal y completar la operaci\u00f3n de medici\u00f3n de caudal ADCP.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/HD-MAX.jpg\" width=\"90%\" alt=\"\"><\/figure>\n<h2><em><span style=\"color: #186bb5;\"><strong>Flujo de trabajo<\/strong><\/span><\/em><\/h2>\n<p><span style=\"font-size: 14pt;\"><em><strong>1. Instalaci\u00f3n del equipo<\/strong><\/em><\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\">Para reducir el error de medici\u00f3n causado por la distancia entre cada dispositivo durante la medici\u00f3n conjunta, el ADCP iFlow RP600 se instal\u00f3 lateralmente en la parte frontal derecha del buque de investigaci\u00f3n de acero. La ecosonda de doble frecuencia HD-MAX DF se instal\u00f3 delante del ADCP iFlow RP600 para reducir la distancia entre ambos. Las dos antenas direccionales de posicionamiento del RTK dividido de alta precisi\u00f3n K20 se instalaron directamente sobre el soporte fijo del ADCP iFlow RP600. Para mejorar la precisi\u00f3n y la calidad de la medici\u00f3n conjunta, los probadores de Hi-Target realizaron una correcci\u00f3n de desviaci\u00f3n de -4\u00b0 entre la l\u00ednea base de la antena del RTK dividido de alta precisi\u00f3n K20 y el \u00e1ngulo de rumbo de la instalaci\u00f3n del ADCP iFlow RP600.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/04_\u753b\u677f-1-2.png\" alt=\"ecosonda lateral\" width=\"50%\" \/><\/figure>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/side-echo-sounder.jpg\" alt=\"ecosonda lateral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-size: 14pt;\"><em><strong>2. Recopilaci\u00f3n de datos<\/strong><\/em><\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\">En esta medici\u00f3n de caudal, el iFlow RP600 ADCP realiz\u00f3 dos rondas de medici\u00f3n (un total de cuatro medias rondas de medici\u00f3n). La hora de inicio y los archivos de datos registrados de cada prueba se muestran en la tabla de la derecha.<\/span><br \/>\n<span style=\"font-size: 14pt;\"><em><strong>3. An\u00e1lisis de datos<\/strong><\/em><\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\">Con base en el software de medici\u00f3n de flujo iFlow, se puede obtener informaci\u00f3n diversa, como el perfil de velocidad de flujo general de la secci\u00f3n de prueba de la secci\u00f3n de Luokou.<br \/>\nBas\u00e1ndose en el software de medici\u00f3n de caudal iFlow, es posible obtener los valores de caudal, velocidad, \u00e1rea, ancho del r\u00edo y otros par\u00e1metros obtenidos a partir de la medici\u00f3n actual de la secci\u00f3n transversal y del an\u00e1lisis y c\u00e1lculo estad\u00edstico de los datos.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/07_\u753b\u677f-1-1.png\" alt=\"ecosonda lateral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Bas\u00e1ndose en el software de medici\u00f3n de caudal iFlow, es posible obtener un diagrama esquem\u00e1tico de la curva del caudal medido de toda la secci\u00f3n en funci\u00f3n del tiempo de medici\u00f3n, obteniendo as\u00ed claramente la tendencia del cambio de caudal con el tiempo.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/08_\u753b\u677f-1-2.png\" alt=\"ecosonda lateral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Bas\u00e1ndose en el software de medici\u00f3n de flujo iFlow, se puede obtener la velocidad del flujo y la intensidad del eco medidas por el ADCP iFlow RP600 correspondientes a los 4 haces en cada tiempo de medici\u00f3n.<br \/>\nBas\u00e1ndose en el software de medici\u00f3n de flujo iFlow, se puede obtener la informaci\u00f3n GNSS correspondiente a cada tiempo de r\u00e1faga.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/09_\u753b\u677f-1-1.png\" alt=\"ecosonda lateral\" width=\"90%\" \/><\/figure>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/10.jpg\" alt=\"ecosonda lateral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Con base en el software de medici\u00f3n de flujo iFlow, se puede obtener la l\u00ednea de trayectoria actual del recipiente de medici\u00f3n de acero y el vector de velocidad de flujo correspondiente.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/11_\u753b\u677f-1.png\" alt=\"ADCP de objetivo de impacto\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Basado en el software de medici\u00f3n de flujo iFlow, la tabla de resultados de flujo se puede generar autom\u00e1ticamente y la informaci\u00f3n de configuraci\u00f3n de la medici\u00f3n actual, los resultados de la medici\u00f3n de par\u00e1metros de flujo y los resultados promedio de la medici\u00f3n se pueden registrar autom\u00e1ticamente.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/12_\u753b\u677f-1.png\" alt=\"ADCP de objetivo de impacto\" width=\"90%\" \/><\/figure>\n<h3><span style=\"color: #186bb5; font-size: 18pt;\"><em><strong>Resultado<\/strong><\/em><\/span><\/h3>\n<p><span style=\"font-family: georgia, palatino, serif;\">La desviaci\u00f3n relativa m\u00e1xima de las 4 medias rondas de medici\u00f3n del iFlow RP600 ADCP es de 2,121 TP\u00b3T, y la desviaci\u00f3n est\u00e1ndar de los par\u00e1metros de velocidad de flujo promedio de la secci\u00f3n transversal, direcci\u00f3n del flujo, ancho del r\u00edo y \u00e1rea de la secci\u00f3n transversal se encuentran entre 0,61 TP\u00b3T y 2,71 TP\u00b3T, lo que cumple con los requisitos de precisi\u00f3n de las especificaciones de medici\u00f3n y logra una alta precisi\u00f3n de prueba. Entre ellos, la desviaci\u00f3n relativa entre el caudal promedio medido por el iFlow RP600 ADCP y el caudal en la Estaci\u00f3n Hidrol\u00f3gica de Luokou publicado por el pron\u00f3stico oficial del d\u00eda es de 1,011 TP\u00b3T. Se puede concluir que los datos medidos por el iFlow RP600 ADCP bajo la condici\u00f3n de una concentraci\u00f3n relativamente alta de sedimentos tienen alta precisi\u00f3n y exactitud, y esta prueba conjunta ha sido un completo \u00e9xito.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/13_\u753b\u677f-1.png\" alt=\"ADCP de objetivo de impacto\" width=\"90%\" \/><\/figure>\n<h3><span style=\"color: #186bb5; font-size: 18pt;\"><em><strong>Resumen del proyecto<\/strong><\/em><\/span><\/h3>\n<p><span style=\"font-family: georgia, palatino, serif;\">La prueba conjunta realizada por la estaci\u00f3n hidrol\u00f3gica de Luokou y Hi-Target muestra que el uso conjunto de Hi-Target iFlow RP600 ADCP, la sonda de doble frecuencia HD-MAX DF y el RTK dividido de alta precisi\u00f3n K20 puede superar la influencia de las duras condiciones de gran contenido de arena y completar la tarea de medici\u00f3n del ADCP, que proporciona m\u00e1s medios y m\u00e9todos para medir el flujo en el entorno del r\u00edo Amarillo con gran contenido de arena.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nEl cuestionario tambi\u00e9n demostr\u00f3 el excelente desempe\u00f1o del ADCP iFlow RP600 en t\u00e9rminos de expansi\u00f3n perif\u00e9rica, instalaci\u00f3n y puesta en marcha, software de soporte y resultados de medici\u00f3n de flujo.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nEn t\u00e9rminos de expansi\u00f3n perif\u00e9rica, iFlow RP600 ADCP se puede utilizar para el c\u00e1lculo del flujo ADCP ingresando otros par\u00e1metros perif\u00e9ricos de manera razonable seg\u00fan la demanda, y el dispositivo tiene una buena compatibilidad perif\u00e9rica.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nPara la instalaci\u00f3n y puesta en servicio, el proceso de instalaci\u00f3n y puesta en servicio del ADCP tipo iFlow RP600 es c\u00f3modo y r\u00e1pido, y la conexi\u00f3n con la ecosonda de doble frecuencia HD-MAX DF y el RTK dividido de alta precisi\u00f3n K20 es confiable y se puede utilizar en entornos con grandes concentraciones de arena.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nPara el software de soporte, el software de medici\u00f3n de flujo iFlow puede presentar una gran cantidad de informaci\u00f3n de medici\u00f3n durante el proceso de prueba y el proceso de an\u00e1lisis de datos una vez completada la medici\u00f3n, y tiene una buena experiencia de usuario.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nPara los resultados de la medici\u00f3n de flujo, la autodesviaci\u00f3n (desviaci\u00f3n est\u00e1ndar) de los datos como flujo, velocidad de flujo, velocidad del fondo y \u00e1rea de la secci\u00f3n transversal medidos por el ADCP iFlow RP600 est\u00e1 dentro de 2.7%, y la precisi\u00f3n de la medici\u00f3n cumple con los requisitos de la especificaci\u00f3n de inspecci\u00f3n de flujo del ADCP.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>La prueba conjunta realizada por la estaci\u00f3n hidrol\u00f3gica de Luokou y Hi-Target muestra que el uso conjunto del ADCP Hi-Target iFlow RP600, la sonda de doble frecuencia HD-MAX DF y el RTK dividido de alta precisi\u00f3n K20 puede superar la influencia de las duras condiciones del gran contenido de arena.<\/p>","protected":false},"author":1,"featured_media":33185,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[110],"tags":[],"featured-events-areas":[],"featured-events-form":[],"featured-events-year":[],"industries-category":[40],"product-model":[137,138,136],"class_list":["post-33166","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-hydrography","industries-category-hydrography","product-model-iboat-bs12-usv","product-model-hd-max--dual-frequency-echo-sounder","product-model-hd-lite-single-beam-echo-sounder"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/posts\/33166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/comments?post=33166"}],"version-history":[{"count":0,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/posts\/33166\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/media\/33185"}],"wp:attachment":[{"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/media?parent=33166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/categories?post=33166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/tags?post=33166"},{"taxonomy":"featured-events-areas","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/featured-events-areas?post=33166"},{"taxonomy":"featured-events-form","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/featured-events-form?post=33166"},{"taxonomy":"featured-events-year","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/featured-events-year?post=33166"},{"taxonomy":"industries-category","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/industries-category?post=33166"},{"taxonomy":"product-model","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/es\/wp-json\/wp\/v2\/product-model?post=33166"}],"curies":[{"name":"gracias","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}