{"id":33166,"date":"2023-08-08T11:37:12","date_gmt":"2023-08-08T03:37:12","guid":{"rendered":"https:\/\/en.hi-target.com.cn\/?p=33166"},"modified":"2025-10-16T09:01:56","modified_gmt":"2025-10-16T09:01:56","slug":"iflow-rp600-adcp-in-high-sand-flow-measurement","status":"publish","type":"post","link":"https:\/\/www.hi-target.com.cn\/fr\/case-study\/hydrography\/iflow-rp600-adcp-in-high-sand-flow-measurement","title":{"rendered":"Application de l&#039;ADCP iFlow RP600 \u00e0 la mesure du d\u00e9bit de sable \u00e9lev\u00e9 du fleuve Jaune"},"content":{"rendered":"<p style=\"text-align: center;\"><span style=\"color: #ff0000; font-size: 14pt;\"><strong><a style=\"color: #ff0000;\" href=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2025\/10\/ADCP-in-high-sand-flow-measurement-of-Yellow-River.pdf\" download=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/ADCP-in-high-sand-flow-measurement-of-Yellow-River.pdf\">CLIQUEZ ICI POUR T\u00c9L\u00c9CHARGER CETTE \u00c9TUDE DE CAS<\/a><\/strong><\/span><\/p>\n<p><em><span style=\"color: #999999;\">Le dispositif de mesure de d\u00e9bit ADCP (Acoustic Doppler Velocity Profiler) est actuellement l&#039;un des \u00e9quipements de mesure de la vitesse et du d\u00e9bit des rivi\u00e8res les plus avanc\u00e9s au monde. Utilisant le principe de l&#039;effet Doppler, il permet aux services hydrologiques d&#039;obtenir des informations en ligne et en temps r\u00e9el sur la vitesse et le d\u00e9bit des rivi\u00e8res. Gr\u00e2ce \u00e0 l&#039;ADCP, les services peuvent suivre l&#039;\u00e9tat de fonctionnement et l&#039;\u00e9volution des lois fluviales, fournir des donn\u00e9es fiables pour la pr\u00e9vention et la gestion des crues, afin de minimiser ou d&#039;\u00e9viter les pertes humaines et mat\u00e9rielles caus\u00e9es par les inondations, et garantir la s\u00e9curit\u00e9 des personnes et des biens.<\/span><\/em><\/p>\n<h2><em><span style=\"color: #186bb5;\"><strong>Contexte du projet<\/strong><\/span><\/em><\/h2>\n<p>La station hydrologique de Luokou, situ\u00e9e sur la rive sud de la digue du fleuve Jaune, dans le bourg de Luokou, ville de Jinan, province du Shandong, surveille et rapporte les r\u00e9gimes hydriques pour le compte de la D\u00e9fense nationale et de la D\u00e9fense g\u00e9n\u00e9rale du fleuve Jaune tout au long de l&#039;ann\u00e9e. Elle fournit ainsi des donn\u00e9es hydrologiques pr\u00e9cises pour la lutte contre les inondations et la s\u00e9cheresse, la planification des ressources en eau, les travaux d&#039;ing\u00e9nierie et le d\u00e9veloppement \u00e9conomique local dans le cours inf\u00e9rieur du fleuve Jaune au Shandong. Avec l&#039;arriv\u00e9e de la saison des crues, affect\u00e9e par la r\u00e9gulation des eaux et des s\u00e9diments et l&#039;affouillement du cours sup\u00e9rieur du fleuve Jaune, les eaux de la partie orientale du fleuve pr\u00e9sentent une forte concentration s\u00e9dimentaire, et le d\u00e9bit et le d\u00e9bit augmentent, ce qui pose constamment \u00e0 la station hydrologique de Luokou la difficult\u00e9 de mesurer le d\u00e9bit dans un environnement \u00e0 forte concentration s\u00e9dimentaire.<\/p>\n<h2><em><span style=\"color: #186bb5;\"><strong>Analyse des points douloureux<\/strong><\/span><\/em><\/h2>\n<p>Dans un environnement \u00e0 forte concentration s\u00e9dimentaire, le courantom\u00e8tre et l&#039;ADCP utilis\u00e9s \u00e0 la station hydrologique de Luokou ne peuvent pas \u00eatre test\u00e9s normalement. L&#039;essai au d\u00e9bitm\u00e8tre est long, environ une heure, et la m\u00e9thode d&#039;essai est relativement complexe, exigeant des exigences \u00e9lev\u00e9es pour la section d&#039;essai. De plus, l&#039;utilisation du courantom\u00e8tre n\u00e9cessite beaucoup de main-d&#039;\u0153uvre, obligeant les op\u00e9rateurs \u00e0 piloter le bateau d&#039;essai pour les essais, et pr\u00e9sente des risques cach\u00e9s pour la s\u00e9curit\u00e9 des personnes. Cependant, lorsque l&#039;ADCP est confront\u00e9 \u00e0 une forte concentration s\u00e9dimentaire, le signal acoustique transmis est rapidement absorb\u00e9 et il est impossible d&#039;obtenir des \u00e9chos efficaces, ce qui rend impossible la mesure des informations de suivi du fond et complique l&#039;obtention de donn\u00e9es de d\u00e9bit et de d\u00e9bit.<\/p>\n<h2><em><span style=\"color: #186bb5;\"><strong>Programme de mise en \u0153uvre<\/strong><\/span><\/em><\/h2>\n<p>En raison des conditions difficiles li\u00e9es \u00e0 la forte concentration de s\u00e9diments dans le fleuve Jaune, l&#039;ADCP ne dispose d&#039;aucune information de suivi du fond et ne peut \u00eatre test\u00e9 s\u00e9par\u00e9ment. C&#039;est pourquoi Hi-Target a propos\u00e9 la solution iFlow RP600 ADCP \u00e9quip\u00e9e d&#039;un \u00e9chosondeur bifr\u00e9quence HD-MAX DF et d&#039;un RTK fractionn\u00e9 haute pr\u00e9cision K20.<br \/>\nDans ce sch\u00e9ma, l&#039;\u00e9chosondeur bifr\u00e9quence HD-MAX DF mesure la profondeur de l&#039;eau afin de compl\u00e9ter les param\u00e8tres de profondeur de l&#039;eau contenus dans les informations de suivi du fond de l&#039;ADCP, tandis que le RTK haute pr\u00e9cision K20 mesure la vitesse, compl\u00e9tant ainsi la vitesse relative au sol de l&#039;\u00e9quipement. Les donn\u00e9es de mesure de chaque appareil sont transmises en temps r\u00e9el au logiciel de mesure de d\u00e9bit iFlow gr\u00e2ce au logiciel d&#039;adaptation de l&#039;\u00e9chosondeur bifr\u00e9quence HD-MAX DF et du RTK haute pr\u00e9cision K20, puis int\u00e9gr\u00e9es aux informations de vitesse relative d&#039;\u00e9coulement mesur\u00e9es par l&#039;ADCP iFlow RP600, afin de calculer le d\u00e9bit et de r\u00e9aliser la mesure de d\u00e9bit de l&#039;ADCP.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/HD-MAX.jpg\" width=\"90%\" alt=\"\"><\/figure>\n<h2><em><span style=\"color: #186bb5;\"><strong>Flux de travail<\/strong><\/span><\/em><\/h2>\n<p><span style=\"font-size: 14pt;\"><em><strong>1. Installation de l&#039;\u00e9quipement<\/strong><\/em><\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\">Afin de r\u00e9duire l&#039;erreur de mesure due \u00e0 la distance entre chaque appareil lors de la mesure des joints, l&#039;iFlow RP600 ADCP est install\u00e9 lat\u00e9ralement \u00e0 l&#039;avant droit du navire de sondage en acier. L&#039;\u00e9chosondeur bifr\u00e9quence HD-MAX DF est install\u00e9 devant l&#039;iFlow RP600 ADCP afin de r\u00e9duire la distance entre lui et l&#039;iFlow RP600 ADCP. Les deux antennes directionnelles de positionnement du RTK haute pr\u00e9cision K20 sont install\u00e9es directement au-dessus du support fixe de l&#039;iFlow RP600 ADCP. Afin d&#039;am\u00e9liorer la pr\u00e9cision et la qualit\u00e9 des mesures des joints, les testeurs Hi-Target ont corrig\u00e9 l&#039;\u00e9cart de -4\u00b0 entre la ligne de base de l&#039;antenne du RTK haute pr\u00e9cision K20 et l&#039;angle d&#039;installation du cap de l&#039;iFlow RP600 ADCP.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/04_\u753b\u677f-1-2.png\" alt=\"\u00e9chosondeur lat\u00e9ral\" width=\"50%\" \/><\/figure>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/side-echo-sounder.jpg\" alt=\"\u00e9chosondeur lat\u00e9ral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-size: 14pt;\"><em><strong>2. Collecte de donn\u00e9es<\/strong><\/em><\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\">Lors de cette mesure de d\u00e9bit, l&#039;iFlow RP600 ADCP a effectu\u00e9 deux s\u00e9ries de mesures (soit quatre demi-s\u00e9ries). L&#039;heure de d\u00e9but et les fichiers de donn\u00e9es enregistr\u00e9s pour chaque test sont indiqu\u00e9s dans le tableau de droite.<\/span><br \/>\n<span style=\"font-size: 14pt;\"><em><strong>3. Analyse des donn\u00e9es<\/strong><\/em><\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\">Sur la base du logiciel de mesure de d\u00e9bit iFlow, diverses informations telles que le profil global de vitesse d&#039;\u00e9coulement de la section d&#039;essai de la section Luokou peuvent \u00eatre obtenues.<br \/>\nSur la base du logiciel de mesure de d\u00e9bit iFlow, il est possible d&#039;obtenir le d\u00e9bit, la vitesse, la surface, la largeur de la rivi\u00e8re et d&#039;autres valeurs de param\u00e8tres obtenues \u00e0 partir de la mesure actuelle de la section transversale et de l&#039;analyse statistique et du calcul des donn\u00e9es.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/07_\u753b\u677f-1-1.png\" alt=\"\u00e9chosondeur lat\u00e9ral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Gr\u00e2ce au logiciel de mesure de d\u00e9bit iFlow, il est possible d&#039;obtenir un sch\u00e9ma de principe de la courbe du d\u00e9bit mesur\u00e9 de toute la section en fonction du temps de mesure, obtenant ainsi clairement la tendance de l&#039;\u00e9volution du d\u00e9bit au fil du temps.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/08_\u753b\u677f-1-2.png\" alt=\"\u00e9chosondeur lat\u00e9ral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Sur la base du logiciel de mesure de d\u00e9bit iFlow, la vitesse d&#039;\u00e9coulement et l&#039;intensit\u00e9 de l&#039;\u00e9cho mesur\u00e9es par l&#039;ADCP iFlow RP600 correspondant aux 4 faisceaux \u00e0 chaque instant de mesure peuvent \u00eatre obtenues.<br \/>\nSur la base du logiciel de mesure de d\u00e9bit iFlow, les informations GNSS correspondant \u00e0 chaque temps de rafale peuvent \u00eatre obtenues.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/09_\u753b\u677f-1-1.png\" alt=\"\u00e9chosondeur lat\u00e9ral\" width=\"90%\" \/><\/figure>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/10.jpg\" alt=\"\u00e9chosondeur lat\u00e9ral\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Sur la base du logiciel de mesure de d\u00e9bit iFlow, la ligne de trajectoire actuelle du r\u00e9cipient de mesure en acier et le vecteur de vitesse d&#039;\u00e9coulement correspondant peuvent \u00eatre obtenus.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/11_\u753b\u677f-1.png\" alt=\"hitarget ADCP\" width=\"90%\" \/><\/figure>\n<p><span style=\"font-family: georgia, palatino, serif;\">Sur la base du logiciel de mesure de d\u00e9bit iFlow, le tableau des r\u00e9sultats de d\u00e9bit peut \u00eatre g\u00e9n\u00e9r\u00e9 automatiquement et les informations de configuration de la mesure actuelle, les r\u00e9sultats de mesure des param\u00e8tres de d\u00e9bit et les r\u00e9sultats moyens de mesure peuvent \u00eatre automatiquement enregistr\u00e9s.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/12_\u753b\u677f-1.png\" alt=\"hitarget ADCP\" width=\"90%\" \/><\/figure>\n<h3><span style=\"color: #186bb5; font-size: 18pt;\"><em><strong>R\u00e9sultat<\/strong><\/em><\/span><\/h3>\n<p><span style=\"font-family: georgia, palatino, serif;\">L&#039;\u00e9cart relatif maximal des quatre demi-tours de mesure de l&#039;iFlow RP600 ADCP est de 2,12%, et l&#039;auto-\u00e9cart (\u00e9cart type) des param\u00e8tres de vitesse d&#039;\u00e9coulement moyenne en section transversale, de direction d&#039;\u00e9coulement, de largeur de la rivi\u00e8re et de surface de la section transversale est compris entre 0,6% et 2,7%, ce qui r\u00e9pond aux exigences de pr\u00e9cision des sp\u00e9cifications de mesure et permet d&#039;obtenir une grande pr\u00e9cision des tests. Parmi ces donn\u00e9es, l&#039;\u00e9cart relatif entre le d\u00e9bit moyen mesur\u00e9 par l&#039;iFlow RP600 ADCP et le d\u00e9bit de la station hydrologique de Luokou publi\u00e9 par les pr\u00e9visions officielles du jour est de 1,01%. On peut conclure que les donn\u00e9es mesur\u00e9es par l&#039;iFlow RP600 ADCP dans des conditions de concentration s\u00e9dimentaire relativement \u00e9lev\u00e9e sont tr\u00e8s pr\u00e9cises et exactes, et que cet essai conjoint a \u00e9t\u00e9 un succ\u00e8s total.<\/span><\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" class=\"size-full wp-image-21661 aligncenter\" src=\"https:\/\/www.hi-target.com.cn\/wp-content\/uploads\/2023\/08\/13_\u753b\u677f-1.png\" alt=\"hitarget ADCP\" width=\"90%\" \/><\/figure>\n<h3><span style=\"color: #186bb5; font-size: 18pt;\"><em><strong>R\u00e9sum\u00e9 du projet<\/strong><\/em><\/span><\/h3>\n<p><span style=\"font-family: georgia, palatino, serif;\">Le test conjoint men\u00e9 par la station hydrologique de Luokou et Hi-Target montre que l&#039;utilisation conjointe de l&#039;ADCP Hi-Target iFlow RP600, du sondeur \u00e0 double fr\u00e9quence HD-MAX DF et du RTK divis\u00e9 de haute pr\u00e9cision K20 peut surmonter l&#039;influence des conditions difficiles de forte teneur en sable et compl\u00e9ter la t\u00e2che de mesure de l&#039;ADCP, qui fournit davantage de moyens et de m\u00e9thodes pour mesurer le d\u00e9bit dans l&#039;environnement du fleuve Jaune \u00e0 forte teneur en sable.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nLe quiz a \u00e9galement d\u00e9montr\u00e9 les excellentes performances de l&#039;iFlow RP600 ADCP en termes d&#039;extension p\u00e9riph\u00e9rique, d&#039;installation et de mise en service, de logiciel de support et de r\u00e9sultats de mesure de d\u00e9bit.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nEn termes d&#039;extension p\u00e9riph\u00e9rique, l&#039;iFlow RP600 ADCP peut \u00eatre utilis\u00e9 pour le calcul du flux ADCP en saisissant d&#039;autres param\u00e8tres p\u00e9riph\u00e9riques de mani\u00e8re raisonnable en fonction de la demande, et l&#039;appareil a une bonne compatibilit\u00e9 p\u00e9riph\u00e9rique.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nPour l&#039;installation et la mise en service, le processus d&#039;installation et de mise en service de l&#039;ADCP de type iFlow RP600 est pratique et rapide, et la connexion avec l&#039;\u00e9chosondeur \u00e0 double fr\u00e9quence HD-MAX DF et le RTK divis\u00e9 haute pr\u00e9cision K20 est fiable et peut \u00eatre utilis\u00e9e dans des environnements avec de grandes concentrations de sable.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nPour le logiciel de support, le logiciel de mesure de d\u00e9bit iFlow peut pr\u00e9senter une multitude d&#039;informations de mesure pendant le processus de test et le processus d&#039;analyse des donn\u00e9es une fois la mesure termin\u00e9e, et offre une bonne exp\u00e9rience utilisateur.<\/span><\/p>\n<p><span style=\"font-family: georgia, palatino, serif;\"><br \/>\nPour les r\u00e9sultats de mesure du d\u00e9bit, l&#039;auto-\u00e9cart (\u00e9cart type) des donn\u00e9es telles que le d\u00e9bit, la vitesse d&#039;\u00e9coulement, la vitesse du fond et la section transversale mesur\u00e9es par l&#039;iFlow RP600 ADCP est compris entre 2,7% et la pr\u00e9cision de mesure r\u00e9pond aux exigences de la sp\u00e9cification d&#039;inspection de d\u00e9bit ADCP.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Le test conjoint men\u00e9 par la station hydrologique de Luokou et Hi-Target montre que l&#039;utilisation conjointe du sondeur double fr\u00e9quence Hi-Target iFlow RP600 ADCP, du sondeur double fr\u00e9quence HD-MAX DF et du RTK divis\u00e9 haute pr\u00e9cision K20 peut surmonter l&#039;influence des conditions difficiles d&#039;une forte teneur en sable.<\/p>","protected":false},"author":1,"featured_media":33185,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[110],"tags":[],"featured-events-areas":[],"featured-events-form":[],"featured-events-year":[],"industries-category":[40],"product-model":[137,138,136],"class_list":["post-33166","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-hydrography","industries-category-hydrography","product-model-iboat-bs12-usv","product-model-hd-max--dual-frequency-echo-sounder","product-model-hd-lite-single-beam-echo-sounder"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/posts\/33166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/comments?post=33166"}],"version-history":[{"count":0,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/posts\/33166\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/media\/33185"}],"wp:attachment":[{"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/media?parent=33166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/categories?post=33166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/tags?post=33166"},{"taxonomy":"featured-events-areas","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/featured-events-areas?post=33166"},{"taxonomy":"featured-events-form","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/featured-events-form?post=33166"},{"taxonomy":"featured-events-year","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/featured-events-year?post=33166"},{"taxonomy":"industries-category","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/industries-category?post=33166"},{"taxonomy":"product-model","embeddable":true,"href":"https:\/\/www.hi-target.com.cn\/fr\/wp-json\/wp\/v2\/product-model?post=33166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}