Why did the tilt measurement exit?

Why did the tilt measurement exit?

The tilt measurement function can eliminate the trouble of alignment and greatly improve work efficiency. Due to the characteristics of IMU module, the initialization state may be exited during the tilt measurement process. Therefore, the following should be noted during the tilt measurement process:

1) If the device remains completely stationary for an extended period, reinitialize it.

2) If the device rotates rapidly on the centering pole (more than 2 revolutions per second) or is poked hard on the ground, reinitialize it.

3) If the tilt measurement icon indicates “Not Initialized” or indicates low tilt measurement accuracy, reinitialize it.

Compartilhar:
Este site utiliza cookies e tecnologias relacionadas, conforme descrito em nossa política de privacidade, para fins que podem incluir análise de desempenho do site, experiência aprimorada do usuário ou publicidade. Você pode optar por consentir com o uso deles ou gerenciar suas próprias preferências.